How to disassemble the iron Phillips

How to repair an iron

If the iron has ceased to heat, you can buy a new one, but often the damage is not very serious, and it can be fixed by yourself. If you're familiar with a screwdriver and a multimeter can handle. For information on how to repair the iron with his own hands and will tell in this article.

Since produce irons very manifold firms, they are slightly different - form, heating rate, the quality of spare parts, etc. But here's the general arrangement is the same. Available:

  • Outsole with built-in TAN. If there is a function steamer, at the bottom there are a number of holes for the steam to escape.
  • Thermostat with a handle, which enables to exhibit the required heating temperature of the sole.
  • Capacity / water tank, which is used for stripping.
  • There is a nozzle for spraying water, forced steam to escape. There are also control the flow rate of steam. With it exhibited frequency ADF evaporated water.
  • It connects to the iron by an electrical cord, which is attached to the terminal block situated at the rear of the plastic cover.

Total electric iron arrangement

Once you are in general familiar with the fact that where there is, you can begin to repair the iron hands.

To work need Screwdriver set - Phillips and flat. Will need a knife or unnecessary plastic card - to hook part of the iron with a latch. To check the integrity of the parts will need a multimeter (how to use it, see here). Another may need a soldering iron - if it is necessary to change some parts.

Tools that may be required under the iron maintenance

Of all the tools, but in the process sometimes need insulating tape or shrink tubing may need to sandpaper pliers.

The first difficulty faced wishing to repair the unit yourself - dismantling. It is not easy and is not obvious. The easiest way to remove the back panel. There are several screws that are visible and loosen that is at work. Also screws can be a latch. So unscrewing all visible fasteners, to hook the cover edge of an old screwdriver or plastic card, separate the cover from the housing.

Beneath it is detected in terminal block which carries the cord. If the cord problems can be further disassemble the iron. But if everything is normal with cord have to disassemble further, and this can cause problems.

Some irons - Philips (Philips), Tefal (Tefal) under the hood there are bolts. They, too, get out. Generally, if you see a mount, remove it.

Remove the back cover - the first thing to do when disassembling iron

As each manufacturer is developing its design, and it often varies from model to model. And because there are difficulties. But there are a few things that are found in virtually any manufacturer.

Immediately necessary to remove the disc and temperature regulator steam release button for which they must be clamped in the fingers and pull up. The buttons can be a latch, so you might need something subtle so that you can overcome them was a bit - you can pry the screwdriver.

To disassemble the iron is necessary to remove the button

In some irons, for example, in the Rowenta, as in the photo, there are bolts on the handle (there are some models Scarlet). If any, unscrew them. By removal button also hides the screw, unscrew it too. Then remove the upper plastic parts. They are usually attached to the snap lock. To make it easier to remove them, the castle can be to have a knife or a piece of plastic (credit card).

Under the covers is usually a number of bolts. Unscrewing them continue disassembly as long as there is no separate body and sole. Unfortunately, more precise recommendations can not be given - too different designs are. What can you advise - proceed slowly and carefully. And a couple of videos on how to disassemble the irons of different brands.

Failure of cord - a fairly common type of failure. With this iron damage may not be included or work in fits and starts, it may be difficult to bask outsole. The cord can bend, curl, at bending points damaged insulation, some wires may grind entirely or partially. If there is such damage, the cord should be replaced regardless of the reason for it or not. In any case, all places with damaged insulation should be insulated.

If any damage begins to repair any iron cord inspection. To accurately determine the normal state it or not, it is necessary to ring. To do this, remove the back cover is sufficient. Becomes accessible terminal block, to which the cable is plugged in. You need a tester or multimeter. Put it in continuity mode, a probe pressed against the one contact plug, a second touch on one of the wires on the board. When you touch the "correct" wire multimeter should issue a squeak. This means that the wire is intact.

Check the integrity of the power cord

Color wire insulation can be anything, but the yellow-green is sure to ground (it should be checked by setting the probe on a small metal plate on the bottom of the fork). The remaining two pins are connected to the plug. Here is one of the two wires should call with the pin to which you pressed the multimeter probe. The same operation is repeated with another pin.

To make sure of serviceability of the cord it should be during continuity mash / twist. Especially in those places where there are problems with insulation. If a squeak from such actions is interrupted - the cord should be replaced. He shall be replaced, and if one or both of the pin "do not call". Perhaps you are lucky and the subsequent repair of the iron you will not need.

Verifying PETN

If the iron is not heated, possibly fired heater. If so, you should buy a new iron, as a replacement will cost about the same amount. But above all we must make sure to blame it TEN.

It outputs a heating element iron

In order to check the heater, we get up to the soleplate. It is closer to the rear, there are two ways out of the heating element. Multimeter translate to the position measuring resistance (1000 ohms), conducting the measurement. If the phone numbers of the order of 25 ° ohms, then heater is normal, if more - burned. As already said, in the case of burnout PETN repair iron is not necessary - cheaper to buy a new one.

Thermostat looks like a plate with a group of contacts and the plastic protruding pin, which then is put on the disc.

This thermostat on the iron

To fit the plate two blades. They set the multimeter test leads and check the performance (prozvanivatsya). In the "Off" sound multimeter should disappear when you turn on and turn in any position he should continue playing.

The damage may consist in the fact that in the "on" position contact is still there - then iron does not heat up at all. Maybe the situation is different - it will not turn off the controller and / or does not respond to the position of the regulator. Both causes of contacts. And, most likely, they scorched.

In the first case, it may interfere with carbon deposits which can be cleaned between contacts thrust piece of sandpaper with fine grain, and a few times "poelozit" of contacts. If nazhdachki not, you can use a nail file, but we have to act carefully - Temperature settings depend on the bending plates. So much they can not be bent.

In the second case - if the iron is not switched off - contacts, possibly burnt - alloys. Iron Repair in this case is to try to separate them. But this is rarely the focus. Out - replace it.

Thermostat from another angle

Maybe another time: the fall contacts could somehow mate. When heating the soleplate curving termoplastina presses the contact groups, but can not contact open. The result is the same - the iron is not switched off during heating. Iron Repair is also similar - try to regain mobility of the plates, taking care not to bend them. If not - change.

Approximately in the same area where the thermostat is installed thermal fuse. He stands in the event of overheating of the soleplate - Iron burn if heated to a dangerous temperature. Usually at this Fuse wearing protective tube and most often it is white.

Iron Repair: Fuse and Continuity

Find contacts, prozvanivatsya. Normally fuse "links" if blown - silence. If desired, the pipe can be pushed, directly to ring - may be an open / burnout of the connecting wires. If the fuse blows - desoldering, look the same, and set it in place.

Thermal exclude from the scheme should not be - it will save from the fire in case of problems with temperature control: simply burn out and iron will not work. Though iron requires repair, your house will be safe.

If iron from almost no steam comes out, and the water in the tank is, the more likely salts clogged holes. You can recover the simple techniques. In dishes with low burs (fit pan) pour the water and vinegar (normal, table). In one liter of water glass vinegar. The second recipe - 250 ml boiling water 2 teaspoons of citric acid. The dishes prepared with liquid fall Disabled iron. The fluid should cover the sole.

Purification of holes for the steam to the iron

Vessel with an iron set on fire, bring to a boil, turn off. Wait until cool. Again warmed up. So you can repeat 3-4 times. Until the brine.

Sometimes from the sprayer stops to go water. Most likely, this is due to the fact that the tube is disconnected. In that case, iron repair lies in the fact that it is necessary to disassemble the panel on which are fixed the injection button, and replace all the pipes, wires.

The second way to clear iron from scale - to disassemble it completely, so that there was one sole. Sole seal with tape so as not leaking water, but you can also put in a bowl. Inside the sole pour hot water with vinegar or citric acid, stand to cool, drain, fill again. This continues for as long as you are not satisfied with the results. After rinse with water and collect.

How to disassemble the iron Philips azur

Good day, dear experts!

I was pulled Iron Philips azur ionic for the purpose of cleaning.

Dismantling occurs sequentially, with the contacts on the sole marker caused the color information of wires that were connected. However, being an enthusiastic cleaning process, I did not notice that the water washed away all contacts with the designation. I ask you to tell which wire to any pin should be connected. In addition, if you are in the future will be something to mark, then do not use it as I do, that you will fall under the arm, in my case it was a children's marker, water-based

Rules Forum is forbidden

"The use of obscene words nickname, site addresses, e-mail'ov and meaningless set of numbers.

xarl. I think it will be corrected.

minotavr_84. from left to right at the last photo

2) double green

How to fix the iron with their hands

To fix the iron with your hands, you need to know how to do this device. Considering iron device. we can say that it is structurally similar to such devices as a kettle or a heater. The differences are only at the destination apparatus and the presence of additional nodes.

In iron, regardless of the country and the manufacturer, there are four main components:

  • heater;
  • plug with a cord;
  • thermal fuse;
  • Temperature regulator.

To iron is joined, follows on the tubular heating element disposed in the base of the device, a voltage is applied. In current models, such as "Roventa9raquo ;, apply powerful heating elements from 1000 to 2300 watts. If you do not interrupt the heating process, the sole instrument is glowing so that will be suitable except for frying eggs, and not for ironing.

In order to prevent excessive heating of the integrated circuit devices in the control device. From the thermostat iron depends heat mode, which is selected based on the type of fabrics: some materials can be ironed at 100 ° C, other necessary parameters 200 C. In most models, which include irons "Braun9raquo ;, the adjusting wheel is located in the upper part of the housing under the handle.

An important hub for security is the fuse. Upon reaching the instrument to extreme temperatures, resulting from a fault, thermal fuse opens the contacts, and the iron will switch off.

Before you repair the iron, check the serviceability of the power line. Most often it cracks in the ground part of the deformation - in front of the body or near the plug. Malfunction can occur gradually, when during ironing flashing indicator light. Such wink means that there is no normal contact and possible oxidation of the terminal.

Another problem occurs more rapidly. With long-term friction wires against each other can break the insulating layer and cause short-circuiting. It is manifested strong cotton, disconnect the other devices and the specific odor characteristic of burnt wiring.

Women differ very impressionable, such situations are hurt deeply. They take damage as a natural disaster and react calls to her husband, the MOE and house management. The best option - first, because to get the iron on again can any man whose hands grow from where they should. Otherwise, you should still apply for a strong half, so that he passed the item to be repaired.

Internet is filled with videos on repair of irons. Many stories devoted to flaws in the supply wires. If the cord near the plug is defective, the device does not need to be dismantled. When the suspicion falls on the part that is hidden the body, without disassembly can not do. To produce, for example, repair of iron "Filips9raquo; with his hands, remove the back cover. Behind her the power cord is at odds on three wires. If the insulation is damaged, you must restore it. If the terminals are corroded, disconnect the wires and clean up problem areas.

The heating element in the current samples is a trusted node and seldom breaks. When this trouble occurs, it is better not to buy a new heater. Simply buy a new iron. But first, make sure that the problem is in PETN.

In all models, the heater contacts are soldered to the contacts of the device and connected to an indicator lamp. If the lamp is lit, and the iron is not hot, then the problem is with Tan.

The most common cause of failure of the heating element is a spiral gap. Another reason may be the lack of contact with the rods of PETN device terminals at the connection points.

In some models the thermal fuse is included in one circuit of the heater and the controller - to another. If the fuse is defective, it is possible to put a false "diagnoz9raquo ;, suspecting heater malfunction. To accurately determine the cause of device failure, it must be completely dismantled.

temperature regime is controlled by a round wheel. It is located in the iron "Azur9raquo; in other models on the body under the handle. By turning the wheel to the right, the heating temperature increases, the left - decrease up to the complete disconnection of PETN.

Wheel acts on the sleeve through a special thermostat or angle steel and attached to the body using clips. The iron "Skarlet9raquo; in other models is enough to pick up the control dial with a screwdriver, so he jumped.

The operating principle of the thermostat is based on the different properties of metals. In the manufacture of this assembly two plates are welded, made of metals having dissimilar coefficients of linear expansion. With these indicators, each plate behave differently. Externally, it looks like this: under the influence of temperature the total plate is bent, causing an open circuit, and the iron is turned on.

To verify the fault of the temperature regulator, it is necessary to disassemble the iron completely.

The handle of the device and the plastic parts of the body are attached to the metal parts of the latches or screws. Even one of the manufacturer is a lot of models, and they all have design features. But the general point there are all kinds.

To disassemble the iron, it is necessary to examine its sharp part, where there is one attachment point. For example, iron Philips screw hides under the handle of the pair of adjustment. To unscrew the screw, it is necessary to turn the knob to the left and pull it up. After removal of the adjustment screw assembly can be unscrewed. In "Braun9raquo model; the screw is hidden under the nozzle cap. Remove the nozzle can be gently pulling toward you. After removing it offers easy access to the screw. Other screws or latches are arranged at the rear of the casing.

Once the plastic of the housing could be removed, consideration should be given iron thermostat. In cold mode pins must be shorted. If there is a special device, it is better to ring node. If the device is not present, you can fine sandpaper to clean the contacts, and then turn on the iron chain.

Blame the fuse and other faults

To establish an iron, you can look at the statistics, which says that 50-60% of faults occur due to the fact that the thermal fuse fails. This assembly is disposable and reusable. The fuses of the first group, as a suicide bomber triggered only once. The node is designed so that when the heating element temperature 240 C circuit is broken. Further use of the instrument is no longer possible without further intervention.

Newer technologies include the use of bimetallic components. Such a thermal fuse capable of breaking irons in extreme situations and then switched on again. If the iron is not working for this reason, it is easiest to throw knot, and to short circuit. This can be done in different ways:

  • by soldering;
  • by crimping a metal rod;
  • switching power supply wires.

In each case it is necessary to achieve a reliable contact.

Another common disease is a problem with the stripping system. Sometimes iron "Bosh9raquo; Button, comprising a process strongly pressed, and the steam is supplied. Repair Bosch iron should begin by loosening the screw back and remove the back cover. Followed by gently pull the two buttons regulating the steam flow upward. They are not fastened and are held on the hubs due to friction. Next, unscrew the screw and the plastic handle to be easily removed. two pumps arranged under the lid, one supplies water to the sprinkler delivers water to the other sole for steam generation. You want to extract the steam pump. At the bottom there is a ball, which is due to the scale adheres to the bottom of the chamber. To solve the problem you need to push the ball into the chamber and collect iron in reverse order.

Whichever iron did not have to fix, you must keep in mind the safety and follow certain rules: to include the device in the network only when necessary; do not try to solve the problem with wet hands; during repairs irons must be installed on a stable, do not miss the current and heat-resistant coating.

How to repair an iron

If the iron has ceased to heat, you can buy a new one, but often the damage is not very serious, and it can be fixed by yourself. If you're familiar with a screwdriver and a multimeter can handle. For information on how to repair the iron with his own hands and will tell in this article.

Since produce irons very manifold firms, they are slightly different - form, heating rate, the quality of spare parts, etc. But here's the general arrangement is the same. Available:

  • Outsole with built-in TAN. If there is a function steamer, at the bottom there are a number of holes for the steam to escape.
  • Thermostat with a handle, which enables to exhibit the required heating temperature of the sole.
  • Capacity / water tank, which is used for stripping.
  • There is a nozzle for spraying water, forced steam to escape. There are also control the flow rate of steam. With it exhibited frequency ADF evaporated water.
  • It connects to the iron by an electrical cord, which is attached to the terminal block situated at the rear of the plastic cover.

Total electric iron arrangement

Once you are in general familiar with the fact that where there is, you can begin to repair the iron hands.

To work need Screwdriver set - Phillips and flat. Will need a knife or unnecessary plastic card - to hook part of the iron with a latch. To check the integrity of the parts will need a multimeter (how to use it, see here). Another may need a soldering iron - if it is necessary to change some parts.

Tools that may be required under the iron maintenance

Of all the tools, but in the process sometimes need insulating tape or shrink tubing may need to sandpaper pliers.

The first difficulty faced wishing to repair the unit yourself - dismantling. It is not easy and is not obvious. The easiest way to remove the back panel. There are several screws that are visible and loosen that is at work. Also screws can be a latch. So unscrewing all visible fasteners, to hook the cover edge of an old screwdriver or plastic card, separate the cover from the housing.

Beneath it is detected in terminal block which carries the cord. If the cord problems can be further disassemble the iron. But if everything is normal with cord have to disassemble further, and this can cause problems.

Some irons - Philips (Philips), Tefal (Tefal) under the hood there are bolts. They, too, get out. Generally, if you see a mount, remove it.

Remove the back cover - the first thing to do when disassembling iron

As each manufacturer is developing its design, and it often varies from model to model. And because there are difficulties. But there are a few things that are found in virtually any manufacturer.

Immediately necessary to remove the disc and temperature regulator steam release button for which they must be clamped in the fingers and pull up. The buttons can be a latch, so you might need something subtle so that you can overcome them was a bit - you can pry the screwdriver.

To disassemble the iron is necessary to remove the button

In some irons, for example, in the Rowenta, as in the photo, there are bolts on the handle (there are some models Scarlet). If any, unscrew them. By removal button also hides the screw, unscrew it too. Then remove the upper plastic parts. They are usually attached to the snap lock. To make it easier to remove them, the castle can be to have a knife or a piece of plastic (credit card).

Under the covers is usually a number of bolts. Unscrewing them continue disassembly as long as there is no separate body and sole. Unfortunately, more precise recommendations can not be given - too different designs are. What can you advise - proceed slowly and carefully. And a couple of videos on how to disassemble the irons of different brands.

Failure of cord - a fairly common type of failure. With this iron damage may not be included or work in fits and starts, it may be difficult to bask outsole. The cord can bend, curl, at bending points damaged insulation, some wires may grind entirely or partially. If there is such damage, the cord should be replaced regardless of the reason for it or not. In any case, all places with damaged insulation should be insulated.

If any damage begins to repair any iron cord inspection. To accurately determine the normal state it or not, it is necessary to ring. To do this, remove the back cover is sufficient. Becomes accessible terminal block, to which the cable is plugged in. You need a tester or multimeter. Put it in continuity mode, a probe pressed against the one contact plug, a second touch on one of the wires on the board. When you touch the "correct" wire multimeter should issue a squeak. This means that the wire is intact.

Check the integrity of the power cord

Color wire insulation can be anything, but the yellow-green is sure to ground (it should be checked by setting the probe on a small metal plate on the bottom of the fork). The remaining two pins are connected to the plug. Here is one of the two wires should call with the pin to which you pressed the multimeter probe. The same operation is repeated with another pin.

To make sure of serviceability of the cord it should be during continuity mash / twist. Especially in those places where there are problems with insulation. If a squeak from such actions is interrupted - the cord should be replaced. He shall be replaced, and if one or both of the pin "do not call". Perhaps you are lucky and the subsequent repair of the iron you will not need.

Verifying PETN

If the iron is not heated, possibly fired heater. If so, you should buy a new iron, as a replacement will cost about the same amount. But above all we must make sure to blame it TEN.

It outputs a heating element iron

In order to check the heater, we get up to the soleplate. It is closer to the rear, there are two ways out of the heating element. Multimeter translate to the position measuring resistance (1000 ohms), conducting the measurement. If the phone numbers of the order of 25 ° ohms, then heater is normal, if more - burned. As already said, in the case of burnout PETN repair iron is not necessary - cheaper to buy a new one.

Thermostat looks like a plate with a group of contacts and the plastic protruding pin, which then is put on the disc.

This thermostat on the iron

To fit the plate two blades. They set the multimeter test leads and check the performance (prozvanivatsya). In the "Off" sound multimeter should disappear when you turn on and turn in any position he should continue playing.

The damage may consist in the fact that in the "on" position contact is still there - then iron does not heat up at all. Maybe the situation is different - it will not turn off the controller and / or does not respond to the position of the regulator. Both causes of contacts. And, most likely, they scorched.

In the first case, it may interfere with carbon deposits which can be cleaned between contacts thrust piece of sandpaper with fine grain, and a few times "poelozit" of contacts. If nazhdachki not, you can use a nail file, but we have to act carefully - Temperature settings depend on the bending plates. So much they can not be bent.

In the second case - if the iron is not switched off - contacts, possibly burnt - alloys. Iron Repair in this case is to try to separate them. But this is rarely the focus. Out - replace it.

Thermostat from another angle

Maybe another time: the fall contacts could somehow mate. When heating the soleplate curving termoplastina presses the contact groups, but can not contact open. The result is the same - the iron is not switched off during heating. Iron Repair is also similar - try to regain mobility of the plates, taking care not to bend them. If not - change.

Approximately in the same area where the thermostat is installed thermal fuse. He stands in the event of overheating of the soleplate - Iron burn if heated to a dangerous temperature. Usually at this Fuse wearing protective tube and most often it is white.

Iron Repair: Fuse and Continuity

Find contacts, prozvanivatsya. Normally fuse "links" if blown - silence. If desired, the pipe can be pushed, directly to ring - may be an open / burnout of the connecting wires. If the fuse blows - desoldering, look the same, and set it in place.

Thermal exclude from the scheme should not be - it will save from the fire in case of problems with temperature control: simply burn out and iron will not work. Though iron requires repair, your house will be safe.

If iron from almost no steam comes out, and the water in the tank is, the more likely salts clogged holes. You can recover the simple techniques. In dishes with low burs (fit pan) pour the water and vinegar (normal, table). In one liter of water glass vinegar. The second recipe - 250 ml boiling water 2 teaspoons of citric acid. The dishes prepared with liquid fall Disabled iron. The fluid should cover the sole.

Purification of holes for the steam to the iron

Vessel with an iron set on fire, bring to a boil, turn off. Wait until cool. Again warmed up. So you can repeat 3-4 times. Until the brine.

Sometimes from the sprayer stops to go water. Most likely, this is due to the fact that the tube is disconnected. In that case, iron repair lies in the fact that it is necessary to disassemble the panel on which are fixed the injection button, and replace all the pipes, wires.

The second way to clear iron from scale - to disassemble it completely, so that there was one sole. Sole seal with tape so as not leaking water, but you can also put in a bowl. Inside the sole pour hot water with vinegar or citric acid, stand to cool, drain, fill again. This continues for as long as you are not satisfied with the results. After rinse with water and collect.

how to disassemble the iron philips 4420

Most irons! Compare irons Tefal, Philips, Bosch, Kambrook | Technocontrol. As disassemble iron Philips GC 3760 / Disassembly Philips GC 3760. Disassembly Steam Iron Philips GC2830 วิธี แกะ เตารีด. What to choose iron or steam KanalBYTOVAYa APPLIANCES HOUSEHOLD APPLIANCES. Philips GC4522 Azur Performer Plus mit herausnehmbarer Kalk-Kassette. How to clean the iron scale PHILIPS GC 4490. How to clean burnt iron. How to disassemble the iron Philips GC 3320, and beyond. Disassembly, cleaning and reassembly of the iron 'Philips Mistral GC2100'. Cleaning the iron from scale. Dismantling the iron Vitek VT-1229, VT-1207, VT-12125 P1. Flowing iron Tefal (((What should I do? A comparative review of irons Philips Azur. Iron Philips GC3320. Repair of electric iron.

[F] Share this video on Facebook

Best funny cats videos.

Iron Repair Tefal, Philips, Braun, Electrolux

In everyday life we ​​use different devices for heating and cooking, cleaning, washing, ironing and many other day to day work. Due to the extreme operating conditions, electric irons are often broken, scratched and hammered. Repair Philips Mistral Iron (Phillips), Bosch Sensixx'x (Bosch), Braun Optistyle (Brown), Tefal Aquagliss TurboPro (Tefal), Electrolux and others can easily hold their own hands at home.

Repair the unit yourself will be much easier if you know how it works and what is done. Structurally, the iron comprises a sole, temperature regulators, fuses, electric cord. Device:

  1. Sole - working part electric iron. That's when her help is carried out the main work of the household appliance. It may consist of stainless steel (Brown Freestyle), ceramics (Tefal Virtuose, Supergliss, Ultragliss Diffusion or Ultimate Anticalc), various metal and non-metal compounds. As can be stainless steel, ultra high strength depending on the material and ultraskolzyaschey t. D .;
  2. Temperature controller is necessary for selecting the operating mode (pressing wool, silk, cotton or synthetics). Sometimes mechanical (used for old-style Clatronic models, Saturn - Saturn, Polaris - Polaris, Rowenta Advancer - Roventa and others) and a bimetallic or electronic (Siemens - Siemens, Redmond - Redmond, Scarlett - Scarlett, Panasonic - Panasonic). Of course, Soviet-style controls are more imperfect, but it is believed that they are safer to use than accurate electronic counterparts;
  3. With the help of thermal fuse is monitored throughout the iron system. This part is responsible for the function Auto. If before this piece was present not all irons, but now it is equipped with almost every model. Element is required for the guarantee of security, for example, if you forgot to turn off the iron, it will not light up, but just to temporarily disable itself;
  4. The power cord is required to supply electric power to the working parts of the device.

In some modern installations of steam (e.g., steam generators, which are also subspecies irons) can be more detail, but the four described forms the basis of any circuit. Typical faults are :

  1. The sole is not heated. The problem often occurs in both expensive Braun Optistyle types of models, Kambrook AKI, Moulinex, and at cheaper International, Orion, Bravissimo and Vitek - Vitek. Likely to require urgent repair a fuse or thermostat. The first may break contacts and the second contacts may be oxidized;
  2. Iron does not turn on. You may need to repair the power cord;

Photos - cord inspection

  • It does not function steam exposure. Problems with the steam generator associated with either a thermostat or a clogged steam slots in the sole. Need cleaning;
  • Do not switch modes - broken temperature controller.

    Photos - repair Tefal

    Consider how to disassemble for repair firm Avantis Tefal irons, comfort, MAGNIT RMI-1525, Delfa, Daewoo and others. Step-by-step instruction:

    1. On the rear wall of the clamping screw is located. It needs to screw and remove the cover. In addition to this open attachment still has a few hidden, they can be under cover to a water tank or a (near) a temperature controller. Recommended videos for its dismantling, that in the vast majority of models this screw has an unusual shape, and the two cavities on the sides and the ridge in the middle..;
    2. When lifting the body, be careful - just check for hidden locks and projections. Many manufacturers equip cover special hooks that are not visible from above. To remove the cover without additional breakdowns of their need to carefully bend the thin knife or a screwdriver;
    3. Capacity, which contains the regulator itself and the pump installed on multiple fixtures (in Bork owners manual (Bourke) and Zelmer three of them). When the screws are removed, you just need to pull the thermostat;

    Photos - location thermostat

    Just note that after dismantling warranty will no longer be provided, so if this is the first independent experience - it is better to carry the iron in the service center.

    Video: Tips on repair Iron Scarlett

    Consider the process of cleaning the soles and inner elements. It is necessary to disassemble the iron and separate the sole. First, it is purged with vacuum furniture (narrow) brush - it is necessary to remove dust and particulate matter. After you are put sole (only if it is metal) in a bowl with water, vinegar or citric acid. In 1 liter of water is taken glass vinegar or 5 spoons acid. Together with the capacity of iron put on fire, heat the bowl and boil for a few minutes. Repeat 5 times.

    Photos - dirty soles

    Apart from such available tools can be used the most common descaler for cleaning pots or kettles. After wipe the device and put it to dry in the day use is not recommended.

    Step by step instructions on how to repair the iron thermostat Silter, Ufesa, Rowenta Steam Force, Bosch TDS or VES:

    1. Disassemble the device, unplug all cables. To check the status of the thermostat a few times it is necessary to rotate in both directions until it stops. When he gets to the end position, it has to operate a group of contacts, and the click is heard;
    2. If it does not click - the defective fuse. There are two options: short-circuit the wires so that the iron has not been disconnected or install a new controller. Of course, the first is cheaper and faster, but the second more reliable and safer;
    3. Brazing can be used most simple hand soldering. In order to replace the need to buy the same item, it is desirable, too, the same brand.

    a little harder clean outsole. if a steam control device refuses to be steamed clothes. Here, the reason lies in the holes clogged condensate. Tips from the Masters:

    1. Carefully push them a q-tip and rotate it several times. It is possible to pre-moisten with alcohol or vinegar;
    2. Progladte salt on cotton clothes. This is an old proven way to quickly to operation and stainless steel soleplate;
    3. If you have problems with ceramic or Teflon iron, it is better to take it on cleaning to the experts. For this work, undertake any workshop.

    What if Iron Rowenta Focus DW, rainford, Philips Elance or Polti Vaporella Forever 1800 Eco Program not included :

    1. The first thing you need to check the power cord. He may like broken over the entire length, and in the place of connection to the iron. To test this, remove the lid, which presses the wire to the terminals, and check them out. If there is a problem is detected, the more likely reason for failure of the wire length. It would be best to simply replace with a new power cord;

    Photos - Mount Cord

    It is worth noting that if the soles cracked or burned circuit, then carry out repairs on their own impractical. Or better once referred to specialists (if expensive model, for example, Philips pro Azur), or buy a new iron (if broken Elco, Maxima MI, Taurus).

    Consider how much it costs to repair iron (for repairs of thermostat, without details of the cost) in different cities of Russia and CIS countries:

    How to disassemble the iron Phillips

    Video tutorialHow to disassemble the iron Philips GC 3320, and beyond.

    Modern electric iron as opposed to the old fellow is performed many times more features. One of the main - steaming. This function as you use most often, it becomes unavailable due to contamination. To eliminate the blockage that prevents stripping, it is necessary to disassemble the device.

    Attention! If you do not have the required disassembly skills, self-interference can permanently transform your equipment in a pile of parts. Skilled craftsmen Philips service center, specializing in the repair of more than 12 years, will be able to diagnose quickly and accurately and, accordingly, the subsequent competent repair.

    If you are set to carry out the disassembly procedure yourself, the following recommendations read carefully.

    Stepping iron disassembly guide Philips GC 3320

    First, dismantle the rear support by loosening one screw. Further unscrew the bolt 2 according to the figure below.

    Further loosening of the handle-tip slots. To do this with the help of forces pull the plastic piece up.

    Then detach the top cover by pulling up the item, and then screwing the bolt. See figure below.

    Further unscrew one bolt with the upper structure and raise the upper part.

    Disconnect the wires, memorizing the sequence of the initial connection.

    In the inner structure unscrew all visible screws, as shown below.

    Reaching the viscera, we assess the degree of contamination and remove all the obstructions improvised means. When your device is perfectly clean, we begin to build a sequence of steps.

    You can ask the masters of our service center by calling or writing your question on the feedback form.

    Your message has been sent.

    Thank you for your appeal.

    Add a comment

    • August 2017 (11)
    • July 2017 (10)
    • How to configure Smart TV on the Philips TV - Aug 17, 2017
    • How to update the software on your Philips TV - Aug 12, 2017
    • How to connect your Philips TV to the Internet via WiFi - Aug 08, 2017
    • How to connect your phone to your TV Philips - Aug 04, 2017
    • As the phone Philips move from one SIM to another - Aug 04, 2017

    10% of husky

    Information

    Please contact the Philips service center for repair services by professionals, you will find addresses in the contacts.

    * All company names and trademarks are the property of their respective owners and are used on the site is only for the purpose of review. The use of these materials without identifying the source as a reference to http://ru-philips.ru/ prohibited.

    Information on this site does not constitute a public offer. The site is for informational purposes and may contain errors

  • Leave a Reply

    Your email address will not be published. Required fields are marked *

    72 + = 81